Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
5
5-15
2F1C UK.INDD CM 15.07.2011
2 Way Variable Flow Control Valve
Series 2F1C
with check valve
2 way flow control valves series 2F1C provide pressure
and viscosity compensated flow from port A to port B.
The counter direction is blocked (standard) or can be
open via an integral reverse flow check valve (optional).
Function
The compensator spool is located in front of the metering
spool. The metering spool is closed in the neutral position
to avoid undesired initial actuator motion. The oil flow to
open the metering spool has to pass a needle valve (not
shown in the sectional drawing). The needle valve can
be adjusted from the front panel to set the response time
of the 2F1C.
The metering spool is adjusted by the main control knob.
The key lock has three positions:
Lock: Adjustment is locked.
Adjust: Full adjustment is permitted.
Trim: Fine adjustment of +/- 5% is possible.
Features
• 2 way flow control valve
• Subplate mounting according to ISO 6263
• Excellent fine adjustment
• Adjustable response time
• Closed in neutral position
• Optional reverse flow check valve
• 2 sizes, NG10 (3/8“), NG16 (3/4“)
Characteristics / Ordering Code
2 way
flow control
valve
2F1C
Size Adjustment
knob with
lock
B
01 5
Design
series
Code Size
02 NG10 (3/8”)
03 NG16 (3/4”)
Seal
FPM
Reverse
flow check
Options
Code Check valve
0 without check
C with check
Ordering code